Elkhart Brass has a strong global presence in several vertical markets in the industrial fire suppression industry. These markets include Waste and Recycling, Oil & Gas, Mining & Construction, Firefighting, and Wash Down. Elkhart Brass products provide a range of solutions that are designed to meet the flexibility and reliability required for modern fire suppression applications.
Non-Hazardous Applications
System Monitor Options

HydroBlast™
- Rated up to 750 gpm (2900 LPM)
- Rugged 85 brass construction
- Heavy-duty use

Sidewinder® EXM2
- Rated up to 750 gpm (2900 LPM)
- Teflon-impregnated hard-coated finish
- Lightweight aluminum construction

Cobra™ EXM2
- Rated up to 1250 gpm (4750 LPM)
- Teflon-impregnated hard-coated finish
- Lightweight aluminum construction

Scorpion® EXM2
- Rated up to 2500 gpm (9500 LPM)
- Teflon-impregnated hard-coated finish
- Lightweight aluminum construction
| ERCM | EXM2 INDUSTRIAL | WASHDOWN | INTERMEDIATE | PREMIUM | DELUXE | HW HAZARDOUS | NET HAZARDOUS |
| MONITORS | |||||||
| Sidewinder | 250-700 | 250-700 | 250-700 | 250-700 | |||
| Cobra | 1000-1500 | 1000-1500 | 1000-1500 | 1000-1500 | |||
| HydroBlast | 250-700 | 250-700 | 250-700 | 250-700 | 250-700 | ||
| Spitfire | 1250-2000 | 1250-2000 | |||||
| VALVES | |||||||
| Unibody Valve | X | X | Optional | Optional | Optional | ||
| Keystone Valve | Optional | Optional | Optional | ||||
| Water Valve Junction Box | X | Optional | Optional | Optional | |||
| MCP | |||||||
| Wireless EXM Control Package | X | ||||||
| EXM2 Joystick Controller | Optional | Optional | Optional | ||||
| Operator Controls | X | X | Optional | X | X | ||
| Basic Oscillation | X | X | |||||
| Intelligent Oscillation | X | X | X | ||||
| Automatic Responce | X | X | X | ||||
| Cat 5e Ethernet Cable | X | X | X | Optional | |||
| Multimode Fiber | X | X | X | Optional | |||
| Single Mode | Optional | ||||||
| CRC (See features below) | |||||||
| Hydroblast II | X | ||||||
| Basic | Optional | Optional | Optional | Optional | |||
| Intermediate | Optional | Optional | Optional | Optional | |||
| Premium | Optional | Optional | Optional | Optional | |||
| RF | |||||||
| RF Belly Pack Transmitter | Optional | Optional | Optional | Optional | Optional | Optional | |
| EXM2 Wireless (Handheld) | X | Optional | |||||
| RF Receiver (Integral) | Optional | Optional | |||||
| RF Receiver (Hardwired) | Optional | Optional | |||||
| RF Receiver (Networked) | Optional | Optional | Optional | ||||
| CERTIFICATIONS | |||||||
| UL/FM | Optional | ||||||
| ATEX/IECEX | Optional | ||||||
| OTHER | |||||||
| Can + Power Cable | X | x | x | x | |||
| Extender | Optional | ||||||
| 1 Monitor OCP (Hardwired | Optional | Optional | Optional | Optional | Optional | ||
| 1 Monitor OCP (Networked) | Optional | Optional | |||||
| CRC FEATURES | Basic | Hydroblast II | Intermediate | Premium | Deluxe | HW Hazardous | NET Hazardous |
| Programmable Recipe | X | ||||||
| Cat 5e Ethernet | X | X | Optional | Optional | |||
| Multimode Fiber | X | Optional | Optional | ||||
| Singlemode Fiber | Optional | Optional | Optional | ||||
| Physical Operator Controls | |||||||
| 5510 HMI (9" Screen) | x | x | |||||
| Panel View Plus 7 (15" Screen) | Optional | X | X | X | |||
| Aux Control | Optional | Optional | Optional | Optional | |||
| Device Level Ring (DLR) | X | X | X | ||||
| Remote PLC Troubleshooting | X | X | X | ||||
BASIC Leverages the OEM product line for use in Industrial markets. EXM components are utilized with industrial enclosures and power supplies to run the monitor, valve, and electronics. The system comes with one Can bus/Power cable that is 130′ long. This is the max length of a Can Bus.
Good system for firefighting or basic washdown applications that do not require recipes. Each monitor is a stand-alone system. No networking capability is available.
One end has a plug for the monitor and the other has a plug for the valve.
The installer will cut this cable into three pieces – one for connecting the monitor to the MCP, one to connect the valve to the Valve JB, and the last piece connects the MCP to the VJB.
WASHDOWN Forms the basis of the Elkhart Brass washdown system. Each monitor requires a simple MCP that contains a power supply, a Bridgeway, and a network switch that enables connection via Cat 5e or Multimode Fiber Optic cable in a LINEAR network.
Monitor functions are controlled by the Hydroblast II Control Console which includes a small HMI screen and can store and run recipes for up to 8 monitors.
Since all monitor function is controlled by a single PLC, there is a single point of failure; therefore, this system is not intended for life safety applications.
NOTE: Standard Cobra and Sidewinder monitors could be used with this system. The Hydroblast monitor has more accurate sensors which are required for precise washdown applications.
INTERMEDIATE Leverages the OEM product line for use in an industrial market. Offers features that industrial customers may prefer. MCP contains the Elkhart Brass 7073X2 Interface module that takes input from Industrial Switches and Pushbuttons on the door of the enclosure.
To add flexibility, customers can choose the INTERMEDIATE MCP + RF option. This panel contains an integral Hetronic radio receiver that is controlled by a Belly Pack Transmitter.
Each transmitter can control up to 24 monitors, providing a flexible control option for facilities with multiple monitors.
PREMIUM The PREMIUM MCP has a set of operator controls on the door of the enclosure and contains a Compact Logix PLC which adds greater control over the oscillation function (Intelligent Oscillation) as well as the option for automatic response from an external trigger.
This system also leverages the OEM product line for use in an industrial market, but offers features that industrial customers may prefer. The panel also includes a Red Lion Network switch which allows it to be connected to a Control Room Console via Cat 5e Ethernet cable or Multimode Fiber in a LINEAR network.
For greater flexibility and portability of control, the PREMIUM MCP + RF adds a Hetronic Radio Receiver to the control panel. This is paired with a HetronicBelly Pack Transmitter that can control up to 24 individual monitors. Several Control Room Console options can be used with the PREMIUM MCP controls.
Basic CRC offers control of basic monitor functions for up to four B9 A selector switch selects which monitor is being controlled by the single set of buttons and switches. Standard CRC can also control up to four monitors, but replaces the physical switches and buttons found on the Basic CRC with a touch screen HMI. In addition to basic monitor control, this screen allows the user to easily program the oscillation and automatic response functions.
DELUXE This system blends the size and affordability of EXM monitors while harnessing the power and features of the Elkhart Brass ERCM controls customers have come to depend upon. It was designed to seamlessly integrate with existing Spit-Fire ERCM systems as well as new installations.
DELUXE MCP builds on the features of the PREMIUM MCP and adds the following features: One or Two relay circuits to provide discreet control of traditional industrial valves (MOV or Solenoid) or other auxiliary equipment such as pumps.
Device Level Ring (DLR) networking capability. This allows the control panels to be networked to a Control Room Console in a redundant ring that automatically reroutes traffic to maintain uninterrupted communication if any segment is broken.
The Premium HMI has functionality that can identify any breaks in the ring and alert users to the location of the faulty segment. Optional control of an Elkhart Brass Industrial Extender which allows a monitor to be stowed out of the way until it is needed.”
| File | Summary | File Type | Link |
|---|
| File | Summary | File Type | Link |
|---|---|---|---|
| HMI Manual 98559000 |
HMI Remote Control Console(EB #98559000) |
||
| Manual – Networked MCP |
Model #81471127, 81471128, and similar panels. Networked Monitor Control Panel (EB #98606200) |
||
| Manual Electric Actuated Butterfly Valves |
Model #70117000, 70117200, and 70133000 Electric Actuated Butterfly Valves (EB #98378000) |
||
| Manual Networked RF |
Networked RF Manual Model #81520366, 81520370, 81520371 (EB #98386300) |
||
| The Networked RF Manual 98386300 | |||
| Water Valve Wiring Instructions for Industrial System Control Panels |
Model #81471121, 81471127, 81471128, and similar panels. |
docx |
| File | Summary | File Type | Link |
|---|---|---|---|
| Data Sheet – Industrial EXM2 | |||
| Data Sheet – Industrial Valve |
Industrial Electric Butterfly Valve |
||
| Datasheet – FM/UL ERCM – 24359050 Networked OCP |
FM/UL Networked OCP |
||
| Datasheet – FM/UL ERCM – 8147112 Networked MCP (Non-Hazardous) |
FM/UL Networked OCP |
||
| Datasheet – FM/UL ERCM – 81471121 Hardwired MCP |
FM/UL Hardwired OCP |
||
| Datasheet – FM/UL ERCM – 81471128 Networked MCP |
FM/UL Networked MCP |
||
| Datasheet – Industrial ERCM – Remote Control Monitor System |
FM/UL ERCM – 08394053 |
||
| Datasheet – Industrial ERCM – Washdown |
Washdown |
||
| FM/UL ERCM – 24359051 Hardwired OCP |
FM/UL Hardwired OCP |
| File | Summary | File Type | Link |
|---|---|---|---|
| Industrial Fire Protection Redefined |